Skip to content
Julian's Locksmith

Rubidoux, Riverside County

Electric Strike Installation in Rubidoux: Remote Release for the Door You Have

Short answer: Most electric strike installation in Rubidoux uses a fail-secure strike: it stays locked when power drops, and your key still opens the door from outside. A fail-safe strike releases whenever power is cut, which suits a few interior doors but leaves an entrance unlatched during an outage. Tell us how the door should behave and we'll match the hardware.

Electric Strike Installation in Rubidoux, CA — Installing an electric strike for access control

Doors rarely stay quiet while we work, so we plan an electric strike installation around your schedule. Our day starts at 6:30 a.m. every day and runs to 11:30 p.m., weekends included. For a shop that opens at ten, that means the frame work can be finished and the door secured before the first customer. When you call about electric strike installation in Rubidoux, tell us the lock brand if you know it, whether the door is metal, wood or aluminum, and what should open it. A short description often lets us bring the right strike on the first visit.

What to know first in Rubidoux

Strikes aren't universal, and compatibility is where most electric strike installation problems begin. A cylindrical lock, the knob or lever set found on most office doors, uses a rectangular strike at a standard 4-7/8 inch height. A mortise lock has a deeper, differently shaped latch and often a deadlatch that needs its own strike. Narrow-stile aluminum storefront doors usually carry a deadlatch or hookbolt that calls for a strike built for thin frames. Panic hardware with a rim device latch takes yet another type. Beyond the latch, we look at the frame: pressed steel with a reinforced pocket, a wood jamb, or an aluminum extrusion with almost no wall to work with. The backset, the distance from the door edge to the lock center, and the gap between door and frame decide whether the keeper can release freely. Sometimes the answer is a different strike; occasionally it's a different lock. We would rather tell you that at the first visit than after the frame is cut.

What we can do on-site

  • Fail-secure strike installation. Most Rubidoux offices, shops and suites end up with fail-secure hardware. The door stays latched through outages and power-supply failures, so a dead battery can't turn the entrance into an open door. Inside, the lever still works. Outside, a card, button or key still gets in. We wire it, adjust the keeper and test it.
  • Fail-safe strike installation. A fail-safe strike is energized all day, which means heat, continuous draw and a clear plan for outages. We confirm the strike is rated for continuous duty, pair it with a supply that can carry it, and talk through who would be affected if the door unlatched during a blackout before choosing it.
  • Fire-rated frames and listed strikes. If the frame's label is missing or painted over, we say so before cutting. Rated openings get inspected, and a strike without the right listing can fail inspection or put the door's rating at risk. Sometimes the safest recommendation is a different release method altogether, and we will explain what and why.
  • Card, fob and keypad reader integration. Pair a strike with a reader and a controller, and your key list becomes a credential list. We connect the strike to the controller's lock output, set the release time, and test that valid credentials open the door while invalid ones don't. A lost card gets deleted instead of the whole lock being rekeyed.
  • Power supply, wiring and latch monitoring. Latch monitoring lets the system know whether the door is actually latched rather than just closed. A strike with a latchbolt monitor switch, combined with a door-position switch, gives a clean picture: closed, latched, released. We add those when your system or your alarm monitor wants them.

What's different about Rubidoux

Older homes in Rubidoux often have wood jambs, thick paint and plaster that cracks if you look at it. A strike on a home office, a guest unit or a side entry is possible, but the wood needs gentle routing and the old latch may need replacing. We repair the jamb, touch up the paint, and tell you honestly when a smart lock would suit a residence better than a strike.

Inland heat is hard on electronics and hardware. Power supplies in a hot ceiling or an unventilated closet age faster, adhesive labels let go, and a door that swells in afternoon sun can start to bind on its latch, which shows up as a strike that will not release. We mount supplies where air moves, leave tolerance for seasonal movement and recheck alignment after the first hot spell.

Schools, childcare centers, churches and youth programs in family neighborhoods use strikes to control who enters during the day while keeping exits free. A staff member sees a visitor on camera and releases the door. Parents should never meet a propped door, and children must always be able to leave. We emphasize fail-secure operation, short release times and clear instructions for substitute staff.

Example situations

  • Suppose a tax-preparation office installed a fail-safe strike on its front door because someone called it the safe choice. During a utility shutoff in high-wind fire weather, the door would sit unlatched overnight. The fix is simple: swap in a fail-secure strike so the door stays locked through any outage, and add a small battery backup for the reader.
  • Picture a retail suite with double hollow-metal doors, one leaf active and the other held by flush bolts. The owner wants the active leaf released from the front counter. We'd mount the strike in the frame at the active leaf, confirm the inactive leaf stays bolted, keep the lever for free exit, and talk through how deliveries will use the fixed side.
  • A typical call: a small dental office near Rancho Jurupa Regional Park wants its waiting-room door to stay locked between patients. The front desk sits across the room, so hygienists keep walking out to let people in. The door has a Schlage lever on a pressed-steel frame. We'd fit a fail-secure strike, put a release button on the reception counter, and leave the lever and key exactly as they are.
  • Think of a boutique in a strip center off SR-60 with an aluminum storefront door and an Adams Rite deadlatch. The owner often works alone and wants to buzz in delivery drivers from the back counter without leaving a customer. The jamb extrusion is thin, so we'd choose a narrow-frame strike, add a reinforcing plate behind it, and check that the door still closes cleanly against its weatherstripping.

How the visit works

  1. Look at the door and the latch. The survey takes in the whole opening. Which way does the door swing? Is a closer pushing against the latch? Is the frame hollow, filled or wood? Where is the nearest ceiling space for a power supply? Those answers shape the strike model, the cut and the wiring.
  2. Choose the strike and approve the quote. We recommend a strike model, a failure mode and a release method, then write a quote covering hardware, frame work, wiring and testing. If part of the job belongs to an electrician or fire alarm contractor, the quote names that part. Nothing is cut until you approve.
  3. Prepare the frame. This is the careful part: one correct cut and nothing extra. We use the manufacturer's template, check depth against the frame wall, and stop to reassess if we find mortar, a stud, wiring or a fire label. If the frame is too thin, we add reinforcement rather than hoping it holds.
  4. Run the wiring and set up power. We tie the strike into whatever opens it: a desk button, a doorbell relay, a reader's controller or a keypad. Keeping the release signal separate from the power feed makes troubleshooting simple, and a short note inside the panel records what goes where.
  5. Mount and align the strike. We seat the strike, adjust the keeper opening as the manufacturer allows, and test the latch from both sides. If the door is pushing on the latch, we correct the cause, whether hinges, closer or stop, instead of forcing the strike to compensate for it.
  6. Test, demonstrate and hand over. We test every path: power on, power off, release button, reader, key from outside, lever from inside, and a fire alarm signal if one is connected. Then we show you how the door behaves and what to do if it doesn't, and leave you the strike model, voltage and wiring notes.

What affects the cost

  • Failure mode and power equipment. Backup power is optional on fail-secure doors, because the door stays locked and the key works. It matters more on fail-safe doors you want to hold through a short outage, though they will still release once the battery drains. We lay out both options so you can decide.
  • Wire distance and route. Cable is cheap; getting it there isn't. If the supply is across the building, the run crosses a fire-rated wall or the ceiling is hard-lid, labor grows. Sometimes a closer supply or a different release point saves more than any hardware choice.
  • Fire rating, codes, door count and timing. Scheduling shapes price too. Work done during normal hours at one site is simpler than a rushed one. We'd rather do it right across two visits than cut corners in one. Bundle several doors and we can plan materials, wiring and testing in a single pass.

Every job gets a clear quote before any work starts. Call (951) 903-3193 with the details and we'll tell you what to expect for your situation in Rubidoux.

What not to do

  • Choosing fail-safe because it sounds safer. A fail-safe strike releases when power is lost, so a blackout, a tripped breaker or a dead adapter leaves your entrance unlatched. For exterior doors, fail-secure with a keyed lock is usually the better answer.
  • Cutting the pocket too big. A loose, oversized opening weakens the frame, lets the strike rock and looks sloppy. Fixing it takes filler, a plate or a new section of frame. Cutting small to the manufacturer's template and widening only as needed beats the reverse.
  • Leaving a plain spring latch exposed. If the lock has no anti-shim guard, someone can slide a card between door and frame and push the latch back, strike or no strike. A deadlatching lock or a guard plate closes that gap and is worth adding.

What to do before we arrive

  • Plan the install before paint or flooring is finished. Cutting a freshly painted frame leaves touch-up scars, and rough-in before drywall is easier still. If a remodel in Rubidoux is underway, tell the contractor the door will get a strike so power reaches the frame at the right stage.
  • Test the door during an outage by switching off its breaker. With the power off, does the key still work from outside, and does the lever still let people out? If either answer is no, the design needs another look before an emergency, not during one.
  • Think about who stands at the door. A staff member carrying a tray, a parent with a stroller, a person in a wheelchair: the release button should be reachable, the hold time sufficient and the lever easy to push. Accessibility rules apply to doors you secure.
  • Treat credentials like keys. When someone leaves, delete their card or code the same day. On a networked reader that takes seconds; with a shared keypad code, change the code and tell the people who still need it. Keep a short list of who holds what.

Service in Rubidoux

Rubidoux is about 22 miles from our San Bernardino base, roughly 28 minutes in light traffic via Palm Avenue or University Parkway to I-215 South through San Bernardino, Colton and Grand Terrace. When you call, you get an arrival estimate based on where the technician is and the traffic at that moment.

Commercial jobs on busy stretches like Rubidoux Boulevard sometimes need a parking plan, especially for storefront doors or roll-up gates. Let us know about loading zones, red curbs or parking structures before we arrive.

About Rubidoux: Before settling in Southern California, Louis Robidoux became a naturalized Mexican citizen and served as alcalde of Santa Fe, New Mexico.

NeighborhoodsPacific Avenue area, Opal Street area around Rubidoux High School, Sunnyslope, Agua Mansa Road industrial area, Belltown, Flabob Airport and Mennes Avenue area
ZIP codes92509
Main routesSR-60, Mission Boulevard, Rubidoux Boulevard, Market Street
From our San Bernardino baseabout 22 miles via Palm Avenue or University Parkway to I-215 South through San Bernardino, Colton and Grand Terrace, then SR-60 West (Pomona Freeway) at the 60/91/215 interchange in Riverside to exit 50, Rubidoux Boulevard; exit 52A (Market Street) for Belltown and the northeast side, exit 48 (Valley Way) for the west end

Business lock or door work in Rubidoux?

Call (951) 903-3193 with the address, the doors or hardware involved and when the site is open. We'll quote the job before any work starts and book a time within our hours that suits your schedule.

Frequently asked questions

What happens to the door during a power outage?

With a fail-secure strike, the door stays locked, the key works from outside and the lever works from inside. Readers or keypads may stop working unless there's battery backup, so staff would use keys. With a fail-safe strike, the door unlatches when power is lost unless backup power keeps it energized. We explain the outage behavior before you choose.

Can an electric strike work with double doors?

Yes. The strike goes in the frame at the active leaf, and the inactive leaf is held by flush bolts or its own hardware. If both leaves must open, we look at exit devices with electric trim or a removable mullion setup. Double doors take more planning than a single door, so tell us how the second leaf is used.

Can an electric strike go on any door?

Not any door. The strike must match the lock's latch type, the frame needs enough material to hold the strike body, and the door has to latch reliably already. Fire-rated openings need listed models. Frameless glass doors, and doors with no latch at all, call for a different approach such as a magnetic lock. We check the door before recommending anything.

Can you install an electric strike on an aluminum storefront door?

Often, yes, but it takes more care. Narrow-stile doors usually carry a deadlatch or hookbolt, and the thin aluminum jamb needs a strike made for that frame, sometimes with a reinforcing plate behind it. We measure the extrusion and check the glass stops first. In some frames a different electrified option works better, and we'll say so before cutting.

What's the difference between fail-secure and fail-safe?

A fail-secure strike stays locked when power is lost, and the key still works. A fail-safe strike stays locked only while powered and releases when power drops. Entrances usually use fail-secure so an outage doesn't leave the door unlatched. Fail-safe suits interior doors that must free themselves, such as ones tied to a fire alarm. Your fire marshal can settle close cases.

Electric strike or magnetic lock: which should I choose?

If the door has a good latch, a strike is usually better. It keeps free mechanical exit, keeps the door latched in an outage and works with your key. Magnetic locks suit frameless glass and double doors without latches, but they need extra exit hardware and fire-alarm release. We compare both for your door, then recommend one.

How far is Rubidoux from your base?

Rubidoux is about 22 miles from our San Bernardino base, roughly 28 minutes in light traffic. Arrival time depends on traffic and on the job the technician is finishing, so we give you an estimate on the phone before you commit.

Electric Strike Installation in nearby cities

Call now(951) 903-3193

Daily 6:30am–11:30pm