Skip to content
Julian's Locksmith

Monrovia, Los Angeles County

Magnetic Lock Installation in Monrovia: Glass, Double and Office Doors

Short answer: Magnetic locks suit glass doors, double doors, aluminum storefronts and doors where cutting a strike pocket isn't practical. They are a weaker fit where the door must stay locked during an outage, because a maglock lets go when power is lost. In that case we'd look at an electric strike or an electrified lockset instead.

Magnetic Lock Installation in Monrovia, CA — Installing an electric strike for access control

A maglock is installed from the header down, and most of the work happens above your head: drilling the frame, setting brackets, pulling low-voltage cable through the ceiling and landing wires at a power supply. We schedule magnetic lock installation in Monrovia around your hours, starting as early as 6:30 a.m. every day, so a shop can be secure before it opens. We work until 11:30 p.m., weekends included. Tell us the door type, how it swings and who needs to get in. A few photos of the header and door edge help us arrive with the right bracket kit.

Magnetic Lock Installation in Monrovia: what to expect

A magnetic lock draws power the whole time the door is locked, usually from a 12 or 24 volt DC supply, and that supply becomes the heart of the system. A good install has a regulated, fused supply, suppression on the lock circuit so reader electronics don't pick up noise, and a relay arrangement that lets the fire alarm cut power. Battery backup keeps doors locked through short outages, but batteries age and need replacing every few years. A door-position sensor and a bond sensor, which confirms the magnet is actually seated, tell the system when a door is truly secure. In a sound design the reader or keypad tells the controller to release the lock, but the controller does not hold the only path to the exit. The sensor, the button and the fire alarm each have their own independent route, and that separation keeps the door safe when something fails.

What we can do on-site

  • Header-mounted maglocks on outswing doors. Most outswing steel and wood doors in Monrovia can take a standard header-mount lock with little drama. The two tasks that matter are anchoring the magnet to something that won't flex, and aligning the plate within a small fraction of an inch. A weak anchor or a loose plate is where holding force disappears.
  • Aluminum storefront doors and shear locks. Aluminum storefront frames have narrow headers and thin walls. A surface-mounted magnet can need a backing plate inside the extrusion, while a concealed shear lock hides in the header and clamps the top of the door. Shear locks cost more and need the right header depth, but they leave a very clean look.
  • Fire alarm release and code review. Where a fire alarm panel exists, the maglock must drop out when it sounds. We wire the lock's supply through a relay or listed release, document it, and coordinate testing with whoever services your alarm. The panel connection itself may need a fire alarm or low-voltage contractor.
  • Power supplies, battery backup and surge protection. Nothing ruins a maglock install like a weak supply. If voltage sags, the magnet loses holding force; if the supply overheats, it quits. We mount supplies in ventilated spots, check voltage at the lock under load, and avoid sharing power with devices that could add electrical noise.
  • Readers, keypads and controllers. A maglock pairs well with almost any credential: cards, fobs, PIN codes, mobile credentials. What matters is that the controller's relay is rated for the lock and that the exit path never depends on that relay. We match the pieces, then test each credential type.

What's different about Monrovia

Downtown office buildings and older storefronts in Monrovia often have tall glass doors, narrow aluminum headers and landlord rules about visible changes. Magnetic lock installation there is as much about appearance as strength: a concealed shear lock or a slim surface magnet with tidy cable routing. We work out the landlord's requirements first, because many downtown leases require approval before anyone drills the frame or runs cable through common areas.

Shopping-center tenants use maglocks mostly on stockroom, back-of-house and office doors, and sometimes on glass entry doors after hours. The storefront frame belongs to the landlord, and exit rules apply to the rear corridor too. In Monrovia centers we check delivery routes, fire alarm tie-ins and the way back doors are really used, because a maglock that traps an employee carrying inventory is a problem waiting to happen.

Apartment complexes use maglocks on glass-door fitness rooms, leasing offices, package rooms and clubhouses. Residents' expectations are simple: the door opens when they badge, and it opens from inside. Management needs logs, easy credential changes and a way to find a door left ajar. We install door-position switches and clear exit buttons, and we ask early where the fire marshal wants alarm integration.

Example situations

  • Think of a boutique with frameless glass doors on patch fittings and a floor closer. The owner wants after-hours card access but doesn't want holes in the glass. We'd use a glass-door bracket to clamp the armature plate, mount the magnet on a header plate above the door, hide the cable in the soffit, and add a push button and sensor inside so the door always opens for anyone leaving.
  • Picture a records room in a clinic. Only certain staff should enter, and the door is rarely used but must be monitored. We'd install a maglock with a bond sensor and a door-position switch, a reader outside and an exit sensor inside, plus an entry log, so the office manager can tell when the door was opened and whether it was left unsecured.
  • A common puzzle: the door releases, yet it feels stuck for a second. That is residual magnetism, often from a worn armature plate, rust, or a plate tightened too hard. We'd inspect and clean the faces, check alignment, replace the plate or fit a spacer if needed, and verify the door falls free the instant power is cut.
  • Imagine an aluminum storefront in a strip center with a header only a few inches deep. The tenant likes the look of a concealed lock. We'd compare a surface magnet with a backing plate against a shear lock, explain the cost difference and the header depth required, and get the landlord's approval before drilling a frame they own.

Step by step with Julian's Locksmith

  1. Survey the door, header and exit path. On site we measure door thickness and swing, header depth and ceiling access for cable. We ask who uses the door, when and how, and where the fire alarm panel and power sources are. Photos before the visit help, but nothing replaces seeing the door.
  2. Design the release path and quote. We decide which magnet or magnets, which brackets and which release devices the door needs: sensor, button, fire alarm relay and credentials. The written quote shows each piece and flags anything that needs an electrician, fire alarm contractor or building official before work begins.
  3. Mount the magnet and armature plate. We mark the layout, drill and anchor the bracket or backing plate into solid material, and mount the magnet square to the door. The plate goes on the door with through-bolts and a flexible bushing so it can seat flat against the magnet face, and we tighten everything to specification.
  4. Run the power, sensors and fire alarm release. Low-voltage cable runs from the lock to the power supply, sensors, button and controller. We route it through the ceiling or a raceway, keep power and signal wires neatly separated, and label both ends. Fire alarm relays go in the lock's power line and are tested with the alarm contractor.
  5. Program credentials and set the timers. Programming depends on the controller. A standalone keypad takes a few settings; a networked system takes a user list and schedules. We create the first credentials with you, show you how to add and delete them, and leave the settings recorded.
  6. Test every release and hand over. Testing covers power on, power off, credential, push button, motion sensor and fire alarm release, with the door pulled hard against the magnet. We also test the batteries, if installed, and show you how to check the system monthly.

What affects the cost

  • Door type and mounting hardware. Heavy glass, wide double doors and odd headers all add to hardware needs. We would rather quote a solid kit that holds than a cheap bracket that flexes, because a flexing bracket costs holding force and, sooner or later, trust.
  • Exit devices and fire alarm interface. Expect the exit chain to be a substantial part of the quote. Sensors, buttons, signs, relays and testing take time. Cutting corners here is how doors fail inspection or trap people, so we quote it plainly instead of hiding it in a lump sum.
  • Cable route and header access. Short, accessible cable runs through a drop ceiling go quickly. Long runs, finished walls, concrete or fire-rated barriers take longer and may need other trades. We trace the route during the survey and quote the cabling as its own line.

Every job gets a clear quote before any work starts. Call (951) 903-3193 with the details and we'll tell you what to expect for your situation in Monrovia.

Advice before you book

  • Review who holds access a few times a year. Cards and codes pile up as staff, vendors and contractors come and go, and every extra credential is a door that opens for someone. Remove what you no longer need and keep a short list of current holders.
  • Test the exit button and sensor monthly. Press the button and confirm the door releases; walk toward the door from inside and confirm the sensor does the same. Put the test on a calendar, because exit devices are exactly the part nobody notices until it fails.
  • Tell your alarm company before we test the fire alarm release. Tripping the panel can notify the monitoring station and even the fire department, so the alarm contractor needs to schedule it or put the system on test. That is why this part of the job is arranged ahead of time.
  • Put the push button where someone leaving would reach for it, with a clear label. Hide it behind a plant or a counter and it stops being an exit. Staff and visitors should be able to see it without being told.

Mistakes to avoid

  • Powering the lock from a cheap plug-in adapter. Adapters sag, overheat and fail, and when they do the door opens or the lock buzzes. Use a fused, regulated supply with suppression, in a ventilated spot, with labeled wiring. Voltage that sags under load also weakens the magnet, long before the supply fails outright.
  • Installing the lock without an exit plan. A maglock with a card reader and nothing else can trap people if the controller fails while the lock stays energized. A sensor, push button and fire alarm release aren't optional on exit doors, and an inspector will look for them.
  • Drilling tempered glass. Once glass is tempered it can't be drilled or cut, and any attempt can shatter the panel. Use glass-door clamps that grip the edge. If a door was drilled previously, we can judge whether existing holes can be used safely.

Getting to Monrovia

Monrovia is about 44 miles from our San Bernardino base, roughly 48 minutes in light traffic via University Parkway to SR-210 West. When you call, you get an arrival estimate based on where the technician is and the traffic at that moment.

Our path into Monrovia depends on where the previous job wrapped up. Sometimes that's a straight run via Duarte Road; other times it's surface streets the whole way. Either way, you get a heads-up call when the technician is close.

About Monrovia: Monrovia Canyon Park, known for its year-round waterfall, closed after the 2020 Bobcat Fire and later storm damage, then reopened on June 26, 2025.

NeighborhoodsHuntington Drive corridor, Highlands, South Monrovia Island, Station Square Transit Village, Norumbega Drive foothills, Old Town
ZIP codes91016, 91017
Main routesI-210, Foothill Boulevard, Huntington Drive, Myrtle Avenue
From our San Bernardino baseabout 44 miles via University Parkway to SR-210 West (Foothill Freeway), continuing onto I-210 West through Glendora, Azusa and Duarte; exit Myrtle Avenue for Old Town, Station Square and the foothill streets, or Huntington Drive for the west side

Business lock or door work in Monrovia?

Call (951) 903-3193 with the address, the doors or hardware involved and when the site is open. We'll quote the job before any work starts and book a time within our hours that suits your schedule.

Frequently asked questions

Can you put a maglock on a glass door?

Yes. Tempered glass can't be drilled, so we use glass-door brackets that clamp the armature plate to the glass without holes, and we mount the magnet on a header, sidelight or mounting plate. We check the glass thickness, the pivot or hinge condition and the closer first, because a door that sags won't seat against the magnet.

Will a card reader or keypad work with a magnetic lock?

Yes. A reader or keypad signals a controller, which releases the lock for a few seconds. Cards, fobs, PIN codes and mobile credentials all work, as long as the controller's relay is rated for the lock. We connect the reader, set release times and programming, and test each credential type before we leave.

Should I choose a maglock or an electric strike?

If the door has a sound latch and you want free exit, key override and a door that stays locked in an outage, a strike is usually better. If the door is glass, double or has no frame to cut, or the latch can't be used, a maglock fits. We compare both for your door as part of access control installation.

Can you fix a magnetic lock that another installer put in?

Often. We check the mounting, the power supply and the exit chain: sensor, button and fire alarm release. Missing exit devices, weak brackets and marginal power are common. We explain what we found, what needs changing to make the door safe, and what your building official may want to see.

Are magnetic locks allowed on exit doors in California?

They can be, when installed to the exit rules the building code sets: a way for people to leave without special knowledge, such as a sensor and push button, release on fire alarm, and release when power fails. Details vary by building and occupancy, and your fire marshal or building department decides. We design to those rules and tell you what to confirm.

How do you confirm I'm allowed to modify my door?

Before we modify a door or lock, we verify ID and proof that you own, lease or manage the property, and tenants should have their landlord's approval for drilling the frame. It protects you as well as us. Our license is LCO7891, issued by BSIS, and you can verify it at search.dca.ca.gov.

How far is Monrovia from your base?

Monrovia is about 44 miles from our San Bernardino base, roughly 48 minutes in light traffic. Arrival time depends on traffic and on the job the technician is finishing, so we give you an estimate on the phone before you commit.

Magnetic Lock Installation in nearby cities

Call now(951) 903-3193

Daily 6:30am–11:30pm