Fontana, San Bernardino County
Magnetic Lock Installation in Fontana
Short answer: A maglock has no latch, so exit rules drive the design. For people to leave without special knowledge, an exit-side motion sensor, a push button and a fire alarm release normally cut power to the lock, and a power failure frees the door. Your fire marshal or building department has the final say, and we design around it.

A maglock is installed from the header down, and most of the work happens above your head: drilling the frame, setting brackets, pulling low-voltage cable through the ceiling and landing wires at a power supply. We schedule magnetic lock installation in Fontana around your hours, starting as early as 6:30 a.m. every day, so a shop can be secure before it opens. We work until 11:30 p.m., weekends included. Tell us the door type, how it swings and who needs to get in. A few photos of the header and door edge help us arrive with the right bracket kit.
What to know first in Fontana
Because a maglock has no latch, nobody leaving a building can operate a handle to get out; the lock has to let go for them. That is why magnetic lock installation on exit doors follows a pattern. A sensor above the door detects someone approaching from the exit side and cuts power. A push button near the door, wired to interrupt power directly instead of relying on a software setting, gives a second way out. The fire alarm system, and where required the sprinkler system, also cuts power so the door opens in an emergency, and losing power releases the lock by itself. Those requirements come from the building code California adopts, with local amendments, and the building department or fire marshal decides how they apply to your door. Delayed-egress locks, used in some care and retail settings, follow separate rules. We design to your jurisdiction's expectations and note which parts need review, so you aren't guessing when someone with a clipboard visits.
How we can help in Fontana
- Header-mounted maglocks on outswing doors. On an outswing door with a sound header, the magnet mounts on the frame above the door and the armature plate mounts on the door face directly beneath. This is the cleanest magnetic lock installation: a straight bolt-up, short wiring and good alignment. We check the header for strength and anchor into solid material, not drywall.
- Inswing doors, brackets and offset mounts. When a door swings into the secured space, the magnet and plate can't meet face-to-face without help. Bracket kits offset one or both parts so they close squarely. We pick the kit based on door thickness, header depth and swing, then test with the door fully open, closed and under pressure.
- Double doors and paired magnets. Double doors need two locks or a combined unit, one per leaf, plus a plan for the inactive leaf. We align both plates and magnets so each pulls evenly, then check that the meeting edge keeps the leaves from flexing apart. Both leaves release together when power is cut.
- Power supplies, battery backup and surge protection. Battery backup keeps a maglock holding through short outages and brownouts, though the batteries wear out and the door will release once they are exhausted. We size the battery to your preferences, explain the limits, and put a replacement date on the enclosure so the backup is not forgotten.
- Readers, keypads and controllers. A maglock pairs well with almost any credential: cards, fobs, PIN codes, mobile credentials. What matters is that the controller's relay is rated for the lock and that the exit path never depends on that relay. We match the pieces, then test each credential type.
What's different about Fontana
Inland heat stresses power supplies, batteries and plastic parts. A supply in an unvented ceiling can run hot and fail, and backup batteries age faster. Glass and aluminum doors expand in afternoon sun, which can shift plate alignment slightly through the day. We mount supplies where air moves, check alignment hot as well as cool, and put a battery replacement date on the label.
Clinics and medical offices near Martin Tudor Jurupa Hills Regional Park use maglocks on records rooms, medication areas, labs and staff corridors. Some units, such as memory care or behavioral health, use delayed-egress locks under separate rules, which we don't improvise. For ordinary doors we focus on quiet release, door monitoring and clear exits, and we coordinate with your fire alarm service so that testing doesn't disrupt patients.
In new buildings, the best time for magnetic lock installation is during construction, when conduit, power and fire alarm relays can be planned before drywall. If your Fontana project is still going up, we'd rather coordinate with the electrical and fire alarm contractors from the start. Retrofits cost more and risk damaged finishes, while new work lets us choose mounting hardware to suit the frame.
Common situations
- Imagine an aluminum storefront in a strip center with a header only a few inches deep. The tenant likes the look of a concealed lock. We'd compare a surface magnet with a backing plate against a shear lock, explain the cost difference and the header depth required, and get the landlord's approval before drilling a frame they own.
- For example, a fitness studio has double glass doors off a shared hallway near Bono's Historic Orange on Route 66. Members badge in, and the owner wants evening entry without handing out keys. We'd fit a magnet on each leaf, wire both to a card reader and controller, add sensors and a push button inside, and connect a fire alarm relay with the landlord's alarm contractor.
- Say an earlier installer put a maglock on an office door with a card reader and nothing else. There is no exit button, no sensor and no link to the fire alarm. We'd survey the door, explain what is missing, add a sensor, a push button and a release relay, and tell you honestly which parts the building official will care about.
- In a two-story office building, a corridor door leads to a stair enclosure, and someone wants card access on it. Stair doors have specific rules because people must be able to leave the stair in an emergency. We'd talk with the property manager and the fire marshal before touching the door, since the right answer may be a different lock or no change at all.
Step by step with Julian's Locksmith
- Survey the door, header and exit path. On site we measure door thickness and swing, header depth and ceiling access for cable. We ask who uses the door, when and how, and where the fire alarm panel and power sources are. Photos before the visit help, but nothing replaces seeing the door.
- Design the release path and quote. A good design starts with the exit. We list every way the door releases, then add the credential that lets people in. You see the quote door by door, with notes on what could change. Nothing is drilled until you have approved it.
- Mount the magnet and armature plate. Mounting is about alignment and solid anchorage. We check that the plate meets the magnet fully with the door closed and under slight pressure, that fasteners are tight and that nothing rattles loose. Glass doors use clamps; metal and wood doors use through-bolts.
- Run the power, sensors and fire alarm release. The push button interrupts lock power directly, the sensor does the same through its relay, and the fire alarm relay does it for the building. We test each one independently by operating it with the others disconnected.
- Program credentials and set the timers. Programming depends on the controller. A standalone keypad takes a few settings; a networked system takes a user list and schedules. We create the first credentials with you, show you how to add and delete them, and leave the settings recorded.
- Test every release and hand over. Handover includes a short checklist: monthly button test, periodic cleaning of the plate and magnet face, and battery replacement every few years. We write the lock model, voltage and holding force on a label inside the enclosure, so future service doesn't start with guesses.
What affects the cost
- Door type and mounting hardware. The door decides the bracket, and the bracket decides much of the cost. A standard header mount is inexpensive; custom or concealed mounting costs more. We show the price of each practical option so you can compare the clean look of a shear lock with a surface magnet.
- Holding force and number of leaves. More force isn't always better. A magnet rated beyond what the door and frame can take adds expense without adding security, since the door will fail elsewhere. We choose a force that matches the door's weight, the frame's strength and the value of what is behind it.
- Exit devices and fire alarm interface. Fire alarm interface varies. Some buildings have a simple relay available; others require the alarm contractor to do the work or sign off. We tell you which situation you are in during the survey, so the schedule and budget account for it.
Every job gets a clear quote before any work starts. Call (951) 903-3193 with the details and we'll tell you what to expect for your situation in Fontana.
Mistakes to avoid
- Assuming holding force equals security. A 1,200-pound magnet on a door with weak hinges, a thin frame or a gap at the edge can still be forced somewhere else. The door, the frame and the hinges matter as much as the magnet.
- Mounting the magnet to a hollow, thin or flexible header. It may feel solid when installed and then give way under a hard pull. Anchor into steel, solid blocking or a backing plate that spreads the load across the frame.
- Powering the lock from a cheap plug-in adapter. Adapters sag, overheat and fail, and when they do the door opens or the lock buzzes. Use a fused, regulated supply with suppression, in a ventilated spot, with labeled wiring. Voltage that sags under load also weakens the magnet, long before the supply fails outright.
Advice before you book
- Replace backup batteries on a schedule. A sealed battery typically needs replacing every few years, and a tired one may carry the lock for a short time instead of hours. Write the install date on the battery itself and put the next replacement on your calendar.
- Walk the door as it stands. Does it close fully by itself? Does it sag? Does the closer slam it? A maglock can't fix a door that doesn't meet the frame. Adjust the hinges and closer first, because the plate and magnet need to meet flat every time.
- Think about off-hours security. A maglock lets go when power fails, so a blackout can leave a door unlocked. If that matters overnight, consider battery backup, a separate keyed lock where exit rules allow it, or an electric strike. Each has tradeoffs, and we will walk through them.
- If you rent, ask the landlord in writing before anyone drills the frame. A maglock may need removal when you leave, so keep a copy of the wiring diagram, the model information and any hardware that was taken out. The next tenant, and your landlord, will thank you.
Getting to Fontana
Fontana is about 16 miles from our San Bernardino base, roughly 22 minutes in light traffic via Palm Avenue to I-215 South. When you call, you get an arrival estimate based on where the technician is and the traffic at that moment.
Stuck on the shoulder or in a parking lot along SR-210? Get somewhere safe, turn on your hazards, and give us the nearest exit or business so we can find the car without guessing.
About Fontana: The Fontana Metrolink station on Orange Way opened on November 22, 1993, beside downtown, and serves the San Bernardino Line.
| Neighborhoods | Hunter's Ridge, Central Fontana, Village of Heritage, Southridge Village, Downtown Fontana, Panorama |
|---|---|
| ZIP codes | 92335, 92336, 92337 |
| Main routes | I-10, I-15, SR-210, Sierra Avenue |
| From our San Bernardino base | about 16 miles via Palm Avenue to I-215 South, then SR-210 West (Foothill Freeway) to the Sierra Avenue exit and south into downtown; I-215 North to I-15 South for the Sierra or Summit Avenue exits in North Fontana; I-215 South to I-10 West for Sierra or Cherry Avenue in South Fontana |
Business lock or door work in Fontana?
Call (951) 903-3193 with the address, the doors or hardware involved and when the site is open. We'll quote the job before any work starts and book a time within our hours that suits your schedule.
Frequently asked questions
Can a maglock be used outdoors?
Only models rated for outdoor exposure. Rain, dust, salt air and sun wear out standard indoor magnets. Outdoor-rated units, sealed wire entries and drip protection help, and corrosion-resistant plates matter near the coast. Exterior doors also see more wind and slamming, so the mounting has to be rigid, with the wire entry sealed against water.
Do I need both a motion sensor and a push button?
On most exit doors, yes. The sensor releases the lock when someone approaches; the push button is a second, independent route that interrupts power directly. Some jurisdictions require both, and a single device is a single point of failure. Your fire marshal or building department has the last word, and we build to what they expect.
How do I secure the door after hours if power can fail?
Pair the maglock with battery backup for short outages, and consider a mechanical keyed lock for longer closures, as long as the exit rules for that door allow it. For doors that must stay locked through any outage, an electric strike or electrified lockset is a better fit. We walk you through which setup suits your door.
Does a magnetic lock connect to the fire alarm?
Where a fire alarm system exists, the maglock normally drops out when it sounds, using a relay in the lock's power line. Some buildings add sprinkler or smoke detector release. The panel connection may need a licensed fire alarm contractor, and the release should be tested with them. We coordinate so testing doesn't surprise your alarm monitor.
Can you fix a magnetic lock that another installer put in?
Often. We check the mounting, the power supply and the exit chain: sensor, button and fire alarm release. Missing exit devices, weak brackets and marginal power are common. We explain what we found, what needs changing to make the door safe, and what your building official may want to see.
Will a card reader or keypad work with a magnetic lock?
Yes. A reader or keypad signals a controller, which releases the lock for a few seconds. Cards, fobs, PIN codes and mobile credentials all work, as long as the controller's relay is rated for the lock. We connect the reader, set release times and programming, and test each credential type before we leave.
How far is Fontana from your base?
Fontana is about 16 miles from our San Bernardino base, roughly 22 minutes in light traffic. Arrival time depends on traffic and on the job the technician is finishing, so we give you an estimate on the phone before you commit.
Related services in Fontana
- Access Control Installation in Fontana
- Electric Strike Installation in Fontana
- Door Access Control in Fontana
- Multi-Door Access Control in Fontana
- Commercial Access Control in Fontana
- Card Access System in Fontana
- Panic Bar Installation in Fontana
- Exit Device Installation in Fontana
- Glass Door Lock Repair in Fontana
- Aluminum Storefront Door Repair in Fontana
Magnetic Lock Installation in nearby cities
- Magnetic Lock Installation in North FontanaSan Bernardino County
- Magnetic Lock Installation in EtiwandaSan Bernardino County
- Magnetic Lock Installation in RialtoSan Bernardino County
- Magnetic Lock Installation in BloomingtonSan Bernardino County
- Magnetic Lock Installation in Glen AvonRiverside County
- Magnetic Lock Installation in Rancho CucamongaSan Bernardino County
- Magnetic Lock Installation in Jurupa ValleyRiverside County
- Magnetic Lock Installation in Glen HelenSan Bernardino County

