Skip to content
Julian's Locksmith

Anaheim, Orange County

Anaheim Magnetic Lock Installation Built Around a Safe Exit

Short answer: A maglock has no latch, so exit rules drive the design. For people to leave without special knowledge, an exit-side motion sensor, a push button and a fire alarm release normally cut power to the lock, and a power failure frees the door. Your fire marshal or building department has the final say, and we design around it.

Magnetic Lock Installation in Anaheim, CA — Installing an electric strike for access control

A maglock has no latch to wear out, no bolt to jam and no keeper to align, which is much of the appeal. It is simply a strong electromagnet and a steel plate. That design suits server rooms, records rooms, stockrooms and offices in Anaheim where a door has to stay shut against a hard pull but open instantly when someone needs to leave. The tradeoff is a dependence on power and a design that must put the exit first. This page explains how magnetic lock installation works, what we check on site, what the code expects and what usually changes the price.

How this works in Anaheim

A magnetic lock draws power the whole time the door is locked, usually from a 12 or 24 volt DC supply, and that supply becomes the heart of the system. A good install has a regulated, fused supply, suppression on the lock circuit so reader electronics don't pick up noise, and a relay arrangement that lets the fire alarm cut power. Battery backup keeps doors locked through short outages, but batteries age and need replacing every few years. A door-position sensor and a bond sensor, which confirms the magnet is actually seated, tell the system when a door is truly secure. In a sound design the reader or keypad tells the controller to release the lock, but the controller does not hold the only path to the exit. The sensor, the button and the fire alarm each have their own independent route, and that separation keeps the door safe when something fails.

Work included on a typical visit

  • Header-mounted maglocks on outswing doors. On an outswing door with a sound header, the magnet mounts on the frame above the door and the armature plate mounts on the door face directly beneath. This is the cleanest magnetic lock installation: a straight bolt-up, short wiring and good alignment. We check the header for strength and anchor into solid material, not drywall.
  • Inswing doors, brackets and offset mounts. When a door swings into the secured space, the magnet and plate can't meet face-to-face without help. Bracket kits offset one or both parts so they close squarely. We pick the kit based on door thickness, header depth and swing, then test with the door fully open, closed and under pressure.
  • Frameless and tempered glass doors. Glass-front shops in Anaheim often have patch fittings, floor closers and a lock never meant to be electronic. A maglock with a glass clamp adds access control without altering the glass. We position the magnet where it looks neat and run the cabling where it stays hidden.
  • Double doors and paired magnets. A pair of doors can use two single magnets, a double-door unit on a shared header, or a magnet on one leaf with flush bolts on the other. The best choice depends on which leaves open, how often, and what the code expects. We map that out during the survey.
  • Readers, keypads and controllers. A reader or keypad tells the controller to release the lock for a few seconds. We connect the reader, controller and lock, set the release time, and configure schedules and credentials. Cards or codes can be canceled instantly, which is far easier than rekeying a door.

What's different about Anaheim

Clubhouses, fitness rooms and pool equipment rooms in gated communities often have glass doors where residents badge in. A maglock allows that without cutting the glass, and credentials can be canceled as residents move. We install weather-protected hardware on exposed doors, record the fire alarm and exit configuration for the management company, and confirm in writing that the board has approved the work.

Shopping-center tenants use maglocks mostly on stockroom, back-of-house and office doors, and sometimes on glass entry doors after hours. The storefront frame belongs to the landlord, and exit rules apply to the rear corridor too. In Anaheim centers we check delivery routes, fire alarm tie-ins and the way back doors are really used, because a maglock that traps an employee carrying inventory is a problem waiting to happen.

Apartment complexes use maglocks on glass-door fitness rooms, leasing offices, package rooms and clubhouses. Residents' expectations are simple: the door opens when they badge, and it opens from inside. Management needs logs, easy credential changes and a way to find a door left ajar. We install door-position switches and clear exit buttons, and we ask early where the fire marshal wants alarm integration.

Example situations

  • Imagine an aluminum storefront in a strip center with a header only a few inches deep. The tenant likes the look of a concealed lock. We'd compare a surface magnet with a backing plate against a shear lock, explain the cost difference and the header depth required, and get the landlord's approval before drilling a frame they own.
  • Say an earlier installer put a maglock on an office door with a card reader and nothing else. There is no exit button, no sensor and no link to the fire alarm. We'd survey the door, explain what is missing, add a sensor, a push button and a release relay, and tell you honestly which parts the building official will care about.
  • In a two-story office building, a corridor door leads to a stair enclosure, and someone wants card access on it. Stair doors have specific rules because people must be able to leave the stair in an emergency. We'd talk with the property manager and the fire marshal before touching the door, since the right answer may be a different lock or no change at all.
  • Think of a boutique with frameless glass doors on patch fittings and a floor closer. The owner wants after-hours card access but doesn't want holes in the glass. We'd use a glass-door bracket to clamp the armature plate, mount the magnet on a header plate above the door, hide the cable in the soffit, and add a push button and sensor inside so the door always opens for anyone leaving.

From your call to the finished job

  1. Survey the door, header and exit path. On site we measure door thickness and swing, header depth and ceiling access for cable. We ask who uses the door, when and how, and where the fire alarm panel and power sources are. Photos before the visit help, but nothing replaces seeing the door.
  2. Design the release path and quote. A good design starts with the exit. We list every way the door releases, then add the credential that lets people in. You see the quote door by door, with notes on what could change. Nothing is drilled until you have approved it.
  3. Mount the magnet and armature plate. We mark the layout, drill and anchor the bracket or backing plate into solid material, and mount the magnet square to the door. The plate goes on the door with through-bolts and a flexible bushing so it can seat flat against the magnet face, and we tighten everything to specification.
  4. Run the power, sensors and fire alarm release. Wiring decides reliability. We use wire of the right gauge for the distance, land connections on terminals instead of twisting wires together, and fuse the supply. Exit devices get their own path, so one failed component can't trap anyone.
  5. Program credentials and set the timers. We enter cards, fobs or codes, set the release time and schedules, and decide what happens if someone holds the door open. A short release time discourages tailgating; a longer one helps people carrying loads. We choose a sensible compromise for your door and write it down.
  6. Test every release and hand over. Testing covers power on, power off, credential, push button, motion sensor and fire alarm release, with the door pulled hard against the magnet. We also test the batteries, if installed, and show you how to check the system monthly.

What affects the cost

  • Door type and mounting hardware. The door decides the bracket, and the bracket decides much of the cost. A standard header mount is inexpensive; custom or concealed mounting costs more. We show the price of each practical option so you can compare the clean look of a shear lock with a surface magnet.
  • Power supply, backup and controller. Backup power is the most common optional upgrade. It keeps doors secure through short outages, but the batteries need replacing and the door still releases when they run out. We explain the tradeoff and price it separately. Decide what you are protecting, and for how long, before choosing battery size.
  • Permits, inspections and timing. Multiple doors, rated corridors and tenant improvement projects involve more coordination. We flag early which parts need a licensed electrician or fire alarm contractor, so your budget reflects the whole job and not only ours. When several trades touch one door, someone should own the schedule, and we are glad to coordinate.

Every job gets a clear quote before any work starts. Call (951) 903-3193 with the details and we'll tell you what to expect for your situation in Anaheim.

Advice before you book

  • If you rent, ask the landlord in writing before anyone drills the frame. A maglock may need removal when you leave, so keep a copy of the wiring diagram, the model information and any hardware that was taken out. The next tenant, and your landlord, will thank you.
  • Review who holds access a few times a year. Cards and codes pile up as staff, vendors and contractors come and go, and every extra credential is a door that opens for someone. Remove what you no longer need and keep a short list of current holders.
  • Aim the exit sensor with care. It should see people approaching from inside, not passers-by outside or sunlight on a glass door. Seal gaps at the bottom of the door and keep paper, signs and decorations out of its view.
  • Walk the door as it stands. Does it close fully by itself? Does it sag? Does the closer slam it? A maglock can't fix a door that doesn't meet the frame. Adjust the hinges and closer first, because the plate and magnet need to meet flat every time.

Common errors that cost time and money

  • Skipping the alignment check. A plate that sits at an angle, or a gap wider than a business card, delivers only a fraction of the rated holding force. Tighten the plate with the door closed, then confirm the faces meet fully.
  • Powering the lock from a cheap plug-in adapter. Adapters sag, overheat and fail, and when they do the door opens or the lock buzzes. Use a fused, regulated supply with suppression, in a ventilated spot, with labeled wiring. Voltage that sags under load also weakens the magnet, long before the supply fails outright.
  • Assuming holding force equals security. A 1,200-pound magnet on a door with weak hinges, a thin frame or a gap at the edge can still be forced somewhere else. The door, the frame and the hinges matter as much as the magnet.

Service in Anaheim

Anaheim is about 51 miles from our San Bernardino base, roughly 55 minutes in light traffic via I-215 South through Colton and Grand Terrace to SR-91 West in Riverside. When you call, you get an arrival estimate based on where the technician is and the traffic at that moment.

If you're close to SR-241, tell us which exit or cross street you're nearest. It trims the last mile and keeps the van from circling a block that looks right on the map but isn't.

About Anaheim: Anaheim was founded in 1857 by German settlers, and its name joins Ana, from the Santa Ana River, with the German word heim, meaning home.

NeighborhoodsPeralta Hills, Anaheim Hills, Anaheim Resort, East Anaheim, Anaheim Canyon, East Hills
ZIP codes92801, 92802, 92804, 92805, 92806, 92807, 92808
Main routesI-5, SR-91, SR-57, SR-241
From our San Bernardino baseabout 51 miles via I-215 South through Colton and Grand Terrace to SR-91 West in Riverside, then SR-91 West through Corona and Santa Ana Canyon into Anaheim (Weir Canyon Road or Imperial Highway for Anaheim Hills, SR-57 or Harbor Boulevard for central Anaheim); alternate via I-10 West and SR-57 South when the 91 is jammed

Business lock or door work in Anaheim?

Call (951) 903-3193 with the address, the doors or hardware involved and when the site is open. We'll quote the job before any work starts and book a time within our hours that suits your schedule.

Frequently asked questions

Do I need both a motion sensor and a push button?

On most exit doors, yes. The sensor releases the lock when someone approaches; the push button is a second, independent route that interrupts power directly. Some jurisdictions require both, and a single device is a single point of failure. Your fire marshal or building department has the last word, and we build to what they expect.

What is magnetic lock installation?

Magnetic lock installation means mounting an electromagnet on the door frame and a steel plate on the door, wiring power to the magnet, and adding the release devices that let people leave. When the magnet is powered it holds the door shut; when power is removed, the door is free. We also program any reader or keypad and test every release path before we leave.

Can you put a maglock on a glass door?

Yes. Tempered glass can't be drilled, so we use glass-door brackets that clamp the armature plate to the glass without holes, and we mount the magnet on a header, sidelight or mounting plate. We check the glass thickness, the pivot or hinge condition and the closer first, because a door that sags won't seat against the magnet.

Does a magnetic lock connect to the fire alarm?

Where a fire alarm system exists, the maglock normally drops out when it sounds, using a relay in the lock's power line. Some buildings add sprinkler or smoke detector release. The panel connection may need a licensed fire alarm contractor, and the release should be tested with them. We coordinate so testing doesn't surprise your alarm monitor.

How do you confirm I'm allowed to modify my door?

Before we modify a door or lock, we verify ID and proof that you own, lease or manage the property, and tenants should have their landlord's approval for drilling the frame. It protects you as well as us. Our license is LCO7891, issued by BSIS, and you can verify it at search.dca.ca.gov.

Can a maglock be used outdoors?

Only models rated for outdoor exposure. Rain, dust, salt air and sun wear out standard indoor magnets. Outdoor-rated units, sealed wire entries and drip protection help, and corrosion-resistant plates matter near the coast. Exterior doors also see more wind and slamming, so the mounting has to be rigid, with the wire entry sealed against water.

How far is Anaheim from your base?

Anaheim is about 51 miles from our San Bernardino base, roughly 55 minutes in light traffic. Arrival time depends on traffic and on the job the technician is finishing, so we give you an estimate on the phone before you commit.

Magnetic Lock Installation in nearby cities

From the blog

Call now(951) 903-3193

Daily 6:30am–11:30pm